• 10.03.2022

Radiation protective material Abris RZv-01-DB

Packaging: corrugated cardboard boxes
TU: 6990-012-52471462-2009

Material elastic baritone filled with radiation-protective Abris Rz-01-DB in the form of a part, covered on both sides with anti-adhesive material.

Radiation protective material Abris RZv-01-DB

Scope of application:

  • manufacture of radiation protective equipment for personnel and patients (radiation-protective mats, radiation-protective screens, screens, protective aprons, collars, plates, etc.), protection of structures of buildings and structures from ionizing radiation (premises, radiation-protective products, etc.), protection of radiation equipment for medical and industrial purposes from hard radiation.

Characteristics:

Color: from beige to dark gray.

Product Release Form: part.

 

Main technical characteristics:

Product Elastic barite-filled radiation-protective material Abris RZv-01-DB in the form of a part covered with anti-adhesion material on both sides.
Application temperature not lower than -20 °С
The main geometric dimensions are:
Width (mm) × thickness (mm)
(10÷500)×(2÷30)
Operating temperature from -40 °С up to +70 °С
Water absorption,%, 24h, maximum 0,2
Tensile strength in the longitudinal direction at max load, MPa, not less 0,5
Flexibility, at (20 ± 5) ° С, radius of beam rounding 15 mm Absence of cracks and breaks
Lead equivalent (100 kV X-ray tube voltage), mm Pb in material thickness:
- 9 mm
1
Storage conditions Store in the factory package in a dry room, avoiding direct sunlight. Shelf life - 12 months.

Method of application:

It is recommended to work with radiation-protective material at an air temperature not lower than minus 10 °C. Work at an air temperature below minus 10 °C (but not below minus 20 °C) can be carried out only after exposure of the radiation-protective material at a temperature of plus (20-30) ° within 24 hours.

Before applying radiation-protective material to the metal surface, it must be cleaned of dirt and dust. Remove the exfoliated outer layer of rust from the rusty surface. The surface should be dried and treated with mastic Abris Rp. Before applying radiation-protective material to a concrete or brick surface, it must be cleaned of dirt, dust, and defective places must be plastered with waterproof polymer-cement compounds. The surface should not have chips, shells, solution surges and other damage with a depth or height of more than 2-3 mm. Loose, crumbling areas must be hardened, the surface must be dried and treated with mastic Abris Rp or primer waterborne Abris VRP.

When working with the Abris grade part RZv-01-DB, it is necessary to remove the release material and attach the part to the insulated surface mechanically using self-cutting screws and pressure strips in accordance with the working design. Install Abris RZsk cord along the edge of the part and attach the next part tightly, without clearances. The second and subsequent layers are applied in a similar manner, overlapping the joints of the parts.

Parts of the brand Abris RZv-01-DB can also be used in the form of panels lined with plastic and fastened with a steel profile.

Workers must be provided with overalls and footwear in accordance with industry standards.

Industry

Healthcare industry.

Ask your question

All fields marked with an asterisk (*) are required