• 18.08.2022

Protocol for determining the airborne sound insulation index of a structure using barite panels Abris

Earlier, we informed you about the pilot testing of the soundproofing properties of Abris Barite panels (TU 23.99.19-021-52471462-2017), which confirmed the decrease in the noise index.

Protocol for determining the airborne sound insulation index of a structure using barite panels Abris

As a result of the tests, a protocol was received from FPG ROSSTRO LLC, St. Petersburg.

Based on the results of the test, the following data are available:

  • single-layer cladding made of Barite panel Abris sml6 pb1,0 1200x600x15, on a metal frame with a base of concrete wall blocks, without filling the frame. Filling of seams and junctions with radiation-protective tape Abris RZsk LB. It has an index of sound insulation of airborne noise Rw - 59 dB.

Below are the requirements for ceilings and walls of hospitals and sanatoriums specified in paragraph No. 9 - “Soundproofing of building envelopes”, SNiP 23-03-2003 Noise protection.

Name and location of the building envelope

Insulation index airborne noise (Rw), dB

14

Walls and partitions between wards, doctors' offices

47

15

Walls and partitions between operating rooms and separating operating rooms from other rooms. walls and partitions, separating wards and doctors' offices from canteens and kitchens

57

16

Walls and partitions separating the wards and offices of doctors from common areas

52

Walls and partitions separating the wards and offices of doctors from common areas.