Main technical characteristics:
Material | Cord coated with anti-adhesive material |
Basic geometric dimensions: Diameter, mm; |
1,7-40 |
Application temperature | not lower than -20 °С |
Operation temperature | from -60 °С to +140 °С |
Water absorption, %, no more | 0,20 |
Bond strength with metal during peeling, N/m, not less | 150 |
Flow resistance at 140 °С, 2h, mm, no more | 2,0 |
Storage conditions | Store in the original packaging in a dry room, avoiding direct sunlight. The shelf life is 24 months. |
Method of application:
Before applying the sealant, the work surface must be prepared — dried, cleaned of dirt and dust, and in winter from ice. Remove the exfoliated outer layer of rust and traces of corrosion from the rusty surface. If necessary, before applying the Outline sealant, the surface must be treated with Abris Rp mastic.
It is not recommended to perform sealing work at an outdoor temperature below minus 20 °C, in rain, snow, fog. At an outdoor temperature below plus 5 °C, work can be carried out only after the sealant has been held for 24 hours at a temperature not lower than plus 15 °C, it is recommended to use thermal equipment during installation.
When working with the cord, it is necessary to remove the anti-adhesive coating on one side of the cord, apply the cord to the work surface, press it tightly or roll it with a roller through the anti-adhesive coating, then remove the remaining anti-adhesive coating.
When working with a sealant, no special protective equipment is required for workers.